P75598- Belkin OmniView Serial Console
Figure 2 Chain Rule of IP Filter
You can add a new IP filtering rule by setting the properties at adding line and then clicking
the button Add. You can remove a rule by clicking the button Remove.
In the example above, the rules applied in the following order:
#1. Those hosts belonging to subnet 192.168.2.x are allowed to access to the Serial
Console (through http port 80).
#2. All hosts are not allowed to access to the Serial Console (through http port 80).
After these rules are applied, only the hosts which belong to the subnet 192.168.2.x can
access to the Serial Console (through http port 80).
In addition to the IP filter chain rule mentioned above, the web interface also provides a
convenient way to Enable / Disable telnet (port 23) or web configuration port (port 80 /
443). These services are mainly for the Serial Console configuration. Click on Enable /
Disable button on Action field will help to add / modify chain rule quickly without the hassle
of manually editing the rule
Note:
In order to get a better text alignment, a VT100-awared telnet
client is preferred to align the text output. PuTTY a one of
recommended telnet clients to get better UI text alignment. It is
downloadable from
http://www.chiark.greenend.org.uk/~sgtatham/putty/download.html.
3.3 Web Server Configuration
The Serial Console Web server supports both HTTP and HTTPS (HTTP over SSL)