Belkin F5D52314 - Cable/DSL Gateway Router Manual de usuario Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
Changing the baud rate on the LANCNC-FAD device
The LANCNC-FAD defaults to 38,400 baud. If a different baud rate is desired, verify
that the CNC can support the new baud rate to ensure that the CNC and the LANCNC-
FAD can communicate. To change the LANCNC-FAD device baud rate, an INI file must
be changed that resides on the LANCNC-FAD. Use a PC to create a text file on a SD
card with the file name LANCNC.INI in the root directory. This file must be text only
and have carriage returns at end of each line. To change the baud rate on the LANCNC-
FAD device to 9600 baud, type CNC=9600 in the first line of the LANCNC.INI file. The
LANCNC.INI file must be text only. The current version of LANCNC-FAD has been
tested at 9,600, 38,400, 57,600 and 115,200 baud.
Example how to change the LANCNC-FAD ftp address to 192.1678.2.113 and the baud
rate to 57600:
CNC=57600
BYE=ON
IP address=192.168.2.113
IP mask=255.255.255.0
IP gateway=0.0.0.0
IP dns=0.0.0.0
To complete the baud rate change, cycle power on the LANCNC-FAD. Enter the correct
baud rate on the CNC with the corresponding CD,8 CD,10 or CD,11.
Using the BYE= parameter
The BYE=OFF is for older CNC's that clear the screen after receiving the BYE
command. The BYE command is important because it closes the serial port and allows
the keyboard of the Control to start functioning again. If the BYE is not sent, press the
MANUAL key or the ENTER key to regain keyboard control. Set the BYE=OFF in the
INI file only if the control version clears the screen after a BYE command. Otherwise
keep it at the default of BYE=ON.
Trouble Shooting Guide
Problem: There is no response from the LANCNC-FAD device.
1. Verify the +7 to +30 VDC power supply is plugged into the device.
2. With power applied, at least one LED should be lit on the device indicating
power.
3. The straight through DB25 cable provided should be connected directly into the
machine. Do not use a null modem cable between the LANCNC-FAD device and
the machine.
4. Verify that the machine version supports the baud rate being used. CD,10 is for
38,400 baud machines. CD,8 is for 9600 baud machines. To verify the machine’s
- 20 -
2008-2009 Calmotion LLC, All rights reserved
Vista de pagina 19
1 2 ... 15 16 17 18 19 20 21 22

Comentarios a estos manuales

Sin comentarios