ZPE 2771864 000 00 EN Page 4 of 11
What is the standby wattage of the system?
Standby power demand per DALI ECG 1-/2-lamp is 200 mW, for 3-/4-lamp it is 500 mW
DALI PROFESSIONAL Controller CONT-4 incl. all DALI supplied couplers consumes 10..25 W depending on the
usage. The controller shows no real standby status because there are many processes in the background even if all
ECGs are switched off by DALI.
How can I integrate parallel a group of switching sensors?
A) Electrical Solution
B) Software Solution in DALIpro GUI
Put all switches into one function and define 'switch linkage' = parallel in Properties / General.
Can I use other input devices than from OSRAM?
Yes, the Siemens DALI Multi Sensor Office 5WG 141-2AB51 is electrical identical to OSRAM DALI Sensorcoupler.
Only label and GTIN = EAN10 stored in the coupler are different.
Also the Siemens DALI Pushbutton Coupler 5WG 141-2AB71 can be used in the OSRAM system.
Is it possible to switch ON/OFF a CONT-4 controller relay K1 with a lightsensor?
You cannot switch ON/OFF with OSRAM DALI Sensorcoupler because the lightsensor is only used for regulation. For
switch function we use the PIR sensor with movement. But to generate a dusk / dawn switch here the trick :
Use an external dawn sensor with switched output (must be dry contact, not mains connected)
and take this as an input to DALI Pushbutton Coupler which is configured as switch.
Can OSRAM DALI SWITCH SO be used with other systems than DALI PROFESSIONAL?
OSRAM DALI SWITCH SO is not only made for use in DALI PROFESSIONAL. It is working similar to an ECG, means
if a DALI controller sends a DALI command with dimmlevel > 1 all 3 relais switch ON, with dimmlevel = 0 they switch
OFF.
Which USB cable do I need to connect DALI PROFESSIONAL to PC?
The connection from OSRAM DALI PROFESSIONAL Controller to PC is made with USB cable Typ A/B, see picture
Usually a PC / notebook provides type A socket (rectangular connector, see left side of picture).
The DALI controller USB input is type B (square connector, see right side of picture).
What is a regulation factor?
The regulation factor is a measure for the split of artificial / natural light in the room in relation to light sensor position.
There are detailed algorithms behind and 2.8 is a standard value for an office. The regulation factor can be calibrated
optional for each application, but this method is made for specialists which need extra accurate regulation. For
standard use cases it is not necessary to calibrate the regualtion factor.