Belkin F1D084Eea Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Servidores De Consola Belkin F1D084Eea. Belkin F1D084Eea User manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - User Manual

OmniView® Serial Console ServerUser ManualF1DP116Sea

Pagina 2 - Table of Contents

6Product Overview SpecificationsNote:Specifications are subject to change without notice.Feature SpecificationGeneralLEDsPower (red) Ready (green, norm

Pagina 3

7section Local Installation WheretoplacetheConsoleServer:The enclosure of the Console Server is designed for stand-alone or rack-mount configurati

Pagina 4

8Local InstallationDesktop or Rack-MountingThe Console Server can be placed on desktops or rack-mounted on 19-inch/1U racks.Note: Before you begin, lo

Pagina 5

9section Local Installation Connecting the Target Devices to the Console Server1. Power down the target device(s) that will be connected to your Con

Pagina 6

10Network ConfigurationBefore you can connect to a target device, you will need to configure the network settings. The Console Server offers two methods

Pagina 7

11section Network ConfigurationNote:HTTPScanbeusedforcommunicationoveranencryptedsecuresocketlayer(SSL).When first connecting to the Conso

Pagina 8

12Network ConfigurationClick . The web interface will open at the “Connect” page (see below). Main-ConnectPageStep3NetworkCon

Pagina 9

13section Network ConfigurationAssigning IP from the Console Port—VT-100 (Console, Telnet, SSH)The Console Server also offers a user-friendly, menu-dri

Pagina 10 - Product Overview

14Network ConfigurationThe following figure depicts the structure of the interface.TheMenuLayoutTier2menuTier1menu Productname Software versionCo

Pagina 11 - Local Installation

15section Network ConfigurationNetwork>IPCongThe page to the left shows the IP configuration items. 1. For IPmode— You can press the SPACE ba

Pagina 12

Table of ContentsProduct Overview...1

Pagina 13

16Network ConfigurationNote:Only the admin user has the privilege to log in to VT-100. All the other users are not authorized to make configuration with

Pagina 14 - Network Configuration

17section Network ConfigurationWhere available, the page will allow users to apply or cancel their actions. To apply all changes, select “Apply” and th

Pagina 15

18Network SettingsYou can configure the network IP settings via VT-100 or web interface. This section describes configuration through the web interface.

Pagina 16

19section Network SettingsIP FilteringThe IP filtering function keeps unauthorized hosts from accessing the Console Server by specifying rules. The IP

Pagina 17

20Network SettingsWhen the Console Server receives a TCP packet, it will process the packet with the chain rule depicted below. The process order is i

Pagina 18

21section Network SettingsAfter these rules are applied, only the hosts that belong to the subnet 192.168.2.x can access the Console Server (through h

Pagina 19

22Network SettingsDynamic DNSIf a user connects the Console Server to a DSL line or uses a DHCP configuration to get a dynamic IP address from the netw

Pagina 20

23section Network SettingsRADIUSAuthentication is the process of identifying an individual, usually based on a user name and password. The Console Ser

Pagina 21

24Network SettingsRADIUS-Server Configuration HTTPS/SSLThe Console Server supports both HTTP and HTTPS (HTTP over SSL) services simultaneously. You can

Pagina 22 - Network Settings

25section Serial PortsConfigurationUnder the “Serial” menu heading, click “Configuration” to show the port summary list. Note that if the “Serial Port”

Pagina 23

Table of ContentsSystem Status and Log ...37Syst

Pagina 24

26Serial PortsPortEnable/DisableEach serial port can be individually enabled or disabled. A disabled serial port cannot be accessed by a user. Users

Pagina 25

27section Serial PortsOperationModesThe Console Server unit provides four types of operation modes. These are described below. Console-ServerModeCon

Pagina 26

28Serial PortsThe following parameters are configurable in console-server mode: ListeningTCPPortNumberYou can also access a serial port through the

Pagina 27 - RADIUS ServerUser Host

29section Serial PortsIn order to terminate a telnet/SSH/RawTCP session in terminal-server mode, you may use these three control-key sequences (Ctrl-Z

Pagina 28

30Serial PortsPortLoggingWhile in console-server mode, the data received from the tracking serial port will be buffered in the unit’s memory. The “Po

Pagina 29 - Serial Ports

31section Serial PortsClick “Port event handling”.The memory buffer size for logging data is 192K per port. If the log data grows larger than the memo

Pagina 30

32Serial PortsUse the hyperlink located at the bottom of the Connect Page to test your Java compatibility. Or use the link below to download the lates

Pagina 31

33section Serial Ports2. Enter the user name and password to log in, so you can start to use it as if you were running a telnet client program (e.g.

Pagina 32

34Serial PortsSerial-to-Serial FunctionThe serial-to-serial function allows you to use a simple terminal device (video display and keyboard) to access

Pagina 33

35section Serial Ports5. Choose the port number to which you wish to connect and the screen below will appear.6. Type in the user name and passwor

Pagina 35

36Serial PortsThe web page also gives read-only settings of the serial-to-serial function; it will automatically change according to the setting chang

Pagina 36

37section System Status and LogSystem StatusThe “System Status” page lists current system information such as name, serial number, firmware versions, M

Pagina 37

38System Status and LogSystem LoggingYou may enable or disable the system-logging process and set the log buffer size. The system log buffer’s default

Pagina 38

39section System AdministrationUser AdministrationAt start-up, the system will prompt the user to enter the password to access the system. The admini

Pagina 39

40System AdministrationThe figure below shows the “Add User” screen.The new user will now appear under the “User Name” list.RemoveUserTo remove a user

Pagina 40

41section System AdministrationEdittheAccessControllist(ACL)The Console Server provides ACL (Access Control List) security where you can specify

Pagina 41 - System Status and Log

42System AdministrationChange PasswordTo change the parameters of the user account, open the “Edit user” screen by selecting the user name on the “Use

Pagina 42

43section System AdministrationFirmware UpgradeFirmware can be easily upgraded via a web page. This section describes the upgrade procedures.The lates

Pagina 43 - System Administration

44System Administration Warning!!!DONOT disconnect the power or the Ethernet cable during this upgrading process. Doing so may cause upgr

Pagina 44

45section System AdministrationOnce all certificate files are uploaded, users shall initiate a reboot command manually to make the new certificate effect

Pagina 45

1section Product Overview IntroductionThank you for purchasing the Belkin OmniView Serial Console Server (Console Server). This device provides admini

Pagina 46

46System Administration

Pagina 47

47section System AdministrationThe other way to tell a secure web connection from an unsafe one is by looking for a lock symbol on your browser (botto

Pagina 48

48System Administration

Pagina 49

49section System AdministrationReset to Factory-Default SettingsTo roll back to factory-default settings, click on “Apply”.RebootYou can trigger the C

Pagina 50

50Technical Data50Default SettingsServerNameDHCPIPAddressNetMaskGatewayBelkinSCEnabled192.168.2.156255.255.255.0192.168.2.1SerialNumberMACAddress

Pagina 51

5151Appendix A: AdaptersF1D120ea (RJ45F–DB9F DTE) DB9FemaleDTEAdapter Applications: Bay Accelar, Nortel, etc. Part No: F1D120ea - Single Pack

Pagina 52

52Appendix A: AdaptersF1D122ea (RJ45F–DB25M DCE) DB25MaleDCEAdapter Applications: Modems Part No: F1D122ea - Single Pack F1D123ea (RJ45F–DB25

Pagina 53

53Appendix A: AdaptersF1D124ea (RJ45F–RJ45M CISCO) RJ45MaleAdapter Applications: Sun devices Part No: F1D124ea - Single Pack F1D124ea8PK - 8

Pagina 54 - Technical Data

545454Appendix B: Ethernet Pin-Outs (RJ45)Standard Ethernet Cable RJ45 Pin-Out Pin Description1 Tx+2 Tx-3 Rx+4 NC5 NC6 Rx-7 NC8 NC

Pagina 55 - Appendix A: Adapters

555555Appendix C: Well-Known TCP/UDP Port NumbersPort numbers are divided into three ranges: Well-Known Ports, Registered Ports, and Dynamic and/or Pr

Pagina 56

2Product Overview Console Server Features• In-bandandout-of-bandmanagementConsole port management solutions offer remote, reliable, and secure acc

Pagina 57

5656Appendix D: Protocol GlossaryBOOTP(BootstrapProtocol)Similar to DHCP, but for smaller networks. Automatically assigns the IP address for a speci

Pagina 58

5757Appendix D: Protocol GlossaryNTP(NetworkTimeProtocol)A protocol used to synchronize time on networked computers and equipment.PAP(PasswordAut

Pagina 59

585858Appendix E: Creating CA FilesThe Console Server supports secure web-page configuration (aka https). There are two types of certificate files for se

Pagina 60 - Appendix D: Protocol Glossary

595959Appendix E: Creating CA Filesii) Strip passphrase:openssl rsa -in cakey.pem -out cakey-nopassword.pemiii) Combine the key and X.509 certificate

Pagina 61

60InformationFCC StatementDECLARATIONOFCONFORMITYWITHFCCRULESFORELECTROMAGNETICCOMPATIBILITYWe, Belkin International, Inc., of 501 West Walnut

Pagina 62 - Appendix E: Creating CA Files

61InformationWhatwillwedotocorrectproblems?Product Warranty.Belkin will repair or replace, at its option, any defective product free of charge

Pagina 63

62InformationHowstatelawrelatestothewarranty.THIS WARRANTY CONTAINS THE SOLE WARRANTY OF BELKIN. THERE ARE NO OTHER WARRANTIES, EXPRESSED OR, EX

Pagina 65

© 2008 Belkin International, Inc. All rights reserved. All trade names are registered trademarks of respective manufacturers listed. Windows is either

Pagina 66

3section Product Overview Equipment Requirements• UniversalConnectivityKit(included)• RJ45-RJ45CAT5Cable(included)System RequirementsWeb brows

Pagina 67

4Product Overview Unit Display DiagramsFront/RearPanelFig. 1 Front ViewFig.2RearViewReadyLEDPowerLEDLinkLEDResetbut-tonIECpower LANportLocal

Pagina 68

5section Product Overview LED Indicators, Button, and Connectors• RESETbutton: Quickly press and release the button to reboot the Console Server. P

Comentarios a estos manuales

Sin comentarios